. OPERATION TROUBLES AND ACTIONS Electronic Control System Machine Monitoring System (*): For details of handling the emergency pump drive switch, swing holding brake cancel switch, and emergency work equipment actuation switch, see "SWITCHES (PAGE 3-16)". 3 - 127 If an error code appears on machine monitor display (1) (n ormally displays TIME), follow the countermeasure table for the self-diagnosis as shown below. Monitor display Error mode Countermeasure E02 Pump control system error If emergency pump drive switch is set to the ON position, operation can be carried out. However, immediately have the system inspected by your Komatsu distributor.
(*) E03 Swing brake system error Turn the swing brake cancel switch ON to release the brake. Depending on the cause of the failure, it may be possible to release the brake. In ant case, have the system inspected immediately by your Komatsu distributor. (*) E05 Governor system error Fuel adjusting dial is inoperative. Either or both of acceleration or deceleration cannot be operated, depending on a failure mode. In any case, call for inspection service immediately. In the case where the monitor will not display error codes and work equipment operation and swing operation cannot be carried out. Have the machine inspected immediately by your Komatsu distributor.