Komatsu — WHEN REQUIRED

. MAINTENANCE SERVICE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING Komatsu genuine SUPERCOOLANT (AF-NAC) has the important function of preventing corrosion as well as preventing freezing. Even in the areas where freezing is not an issue, the use of coolant is essential. Komatsu machines are supplied with SUPERCOOLANT (AF-NAC). SUPERCOOLANT (AF-NAC) has excellent anticorrosion, antifreeze and cooling properties and can be used continuously for 2 years or 4000 hours. As a basic rule, we do not recommend the use of any coolant other than SUPERCOOLANT (AF-NAC). If you use another coolant, it may cause serious problems, such as corrosion of the engine and aluminum parts of the cooling system.

To maintain the anticorrosion properties of coolant, always keep the density of coolant between 30% and 64%. When selecting coolant, investigate the lowest temperature in the past and decide the density for the coolant from the coolant density table below. When actually deciding the density for the coolant, set it approximately 10 ° C (50 ° F) below lowest temperature. The density must be over 30% at least. If the density of obtained coolant is higher than the necessary density for lowest temperature, dilute it with adequate distilled water, and then fill it into the tank. If there is any unclear point, contact your Komatsu distributor.

Coolant density table 4 - 25 Immediately aft er the engine is stop ped, the c oolant i s at high temperatu re and th e radiator i s under high internal pressure. If the radiator c ap is removed in th is conditio n and t he water is drained , it may c ause burns. To preven t this, w ait for the temperature to go down, then turn t he cap slowly to re lease the internal p ressure. Start the engine and flush the syste m. When s tanding up or le aving the o perator's seat, set t he gear shift l ever to N position and set the par king brake switch to PARKING position .

For details of s tarting the engine, s ee "OPERATIONS, CHECK S BEFORE STARTIN G (PAGE 3-85)" and "STARTIN G ENGINE (PAGE 3-86)" in the OPERATION se ction of the Operat ion and M aintenanc e Manual When the unde rcover is removed, t here is danger of to uching t Never go to the front of the machine when the engine is runnin Stop the machin e on level ground when cleaning o r changi ng the co olant.

Clean the inside of the cooling sys tem, change the coolant accordin g to the table below Inte Coolant rval for cleaning inside of cooling system and changing antifreeze coolant Komatsu genuine SUPERCOOLANT (AF-NAC) Every 2 years or every 4000 hours whichever comes sooner Minimum Tem °C Abov p °F Abov e -10 -15 -20 -25 -30 -35 -40 -45 -50 e 14 5 -4 -13 -22 -31 -40 -49 -58 Density (%) 3 0 36 41 46 50 54 58 61 64