Ditch Witch / Charles Machine Works RT40 — 1000 Hour

Service - 134 RT40 Operator’s Manual p 1000 Hour Change Hydraulic Oil and Filter Change hydraulic oil and filter every 1000 hours. To change: 1. Remove drain plug (2). 2. Drain fluid and replace plug. 3. Change filter (see page 130). 4. Add THF at fill (1). until fluid is at halfway point on sight glass (3). Hydraulic reservoir capacity is 9.5 gal (36 L). Hydraulic system capacity is 13 gal (49 L). Change Ground Drive Gearbox Oil Change ground drive gearbox oil every 1000 hours. To change: 1. Remove drain plug (2). 2. Drain oil and replace plug. 3. Add MPL at fill (1) until oil comes out at check plug (2). Capacity is 2 pt (0.96 L).