Komatsu — METHOD OF USE

DETAILED CONTROLS AND GAUGES OPERATION GREASE PUMP 3 This is stored inside the grease pump box on the right side of the chassis. Method of Use 3 1. When power switch (1) is turned on, pump (3) is actuated and grease is sent under pressure to grease gun (2). 2. Grease is discharged when lever for grease gun (2) is pulled. It is possible to check the greasing condition by looking at pressure gauges (4) and (5). (4): green (low pressure) (5): red (high pressure) 3. When the lever of grease gun (2) is released, the supply of grease stops. 4. After using, turn power switch (1) OFF. 3-68