Komatsu — OPERATIONS BEFORE STARTING ENGINE

OPERATION MACHINE OPERATIONS AND CONTROLS 4. The buzzer sounds for approx. 1 second, and the following monitors and meters light up for approx. 3 seconds. q Radiator water level monitor (4) q Engine oil level monitor (5) q Charge monitor (6) q Fuel level monitor (7) q Engine water temperature monitor (8) q Engine oil pressure monitor (9) q Engine water temperature gauge (10) q Fuel gauge (11) q Air cleaner clogging monitor (12) If the monitors do not light up or the buzzer does not sound, there is probably a failure in the monitor, so con- tact your Komatsu distributor for repairs. 5. After approx. 3 seconds, the screen switches to the working mode/travel speed display monitor.

Then it switches to the normal screen. q Fuel level monitor (7) q Engine water temperature monitor (8) q Engine water temperature gauge (10) q Fuel gauge (11) q Hydraulic oil temperature gauge (13) q Hydraulic oil temperature monitor (14) 6. If the hydraulic oil temperature gauge goes out and caution lamp (15) stays lighted up red, carry out inspection immedi- ately for the item which is lighted up red. 3-87