TROUBLES AND ACTIONS OPERATION 2. Loosen air bleed plug (2) at the top of the fuel filter head and open fuel supply valve (1) at the bottom of the fuel tank. 3. Loosen the knob of priming pump (3), pump the knob, and check that fuel comes out from air bleed plug (2). After checking, tighten the plug. Tightening torque: 7.8 to 9.8 N · m (0.8 to 1 kgf · m, 5.8 to 7.2 lbft) 4. Open air breather (4) at the side of the supply pump, and pump priming pump (3) approx. 90 - 100 times. With this operation, fuel will start to overflow from air breather (4). When no more bubbles come out with the fuel, tighten air breather (4). Tightening torque: 4.9 to 6.9 N · m (0.5 to 0.7 kgf · m, 3.6 to 5.1 lbft) 5.
Pump the knob again several tens of times until it becomes stiff, then push in the knob of priming pump (3) and tighten it. 6. If the air is not bled properly, return to Step 3 and bleed the air again. 7. For normal starting operations, turn the key in the starting switch to the START position to start the engine. 3-140