Komatsu — ENGINE

OPERATION TROUBLES AND ACTIONS Engine 3 q ( ): Always contact your Komatsu distributor when dealing with these items. q In cases of abnormalities or causes which are not listed below, please contact your Komatsu distributor for repairs.

3-149 Problem Main causes Remedy Engine oil pressure monitor lights up •Engine oil pan oil level is low (suck- ing in air) •Clogged oil filter cartridge •Defective tightening of oil pipe joint, oil leakage from damaged part •Disconnection, broken wiring to sensor •Add oil to specified level, see CHECK BEFORE STARTING •Replace cartridge, see EVERY 500 HOURS SERVICE (•Check, repair) (•Repair, connect wiring) Steam is emitted from top part of radiator (pressure valve) •Cooling water level low, water •Loosen fan belt •Dirt or scale accumulated in cool- ing system •Clogged radiator fin or damaged fin •Defective engine water tempera- ture gauge •Defective thermostat •Defective thermostat seal •Loose radiator filler cap (high alti- tude operation) •Disconnection, broken wiring to sensor •Add cooling water, repair, see leakage CHECK BEFORE STARTING •Check fan belt tension, see EVERY 500 HOURS SERVICE •Change cooling water, clean inside of cooling system, see WHEN REQUIRED •Clean or repair, see EVERY 500 HOURS SERVICE (•Replace engine water temperature gauge) (•Replace thermostat) (•Replace thermostat seal) •Tighten cap or replace packing (•Repair, connect wiring) Radiator water level monitor lights up Engine water temperature gauge is in red range Engine water temperature monitor lights up Engine water temperature gauge display stays at lowest level and does not rise •Defective water temperature gauge monitor •Defective thermostat •In cold weather, cold wind is blow- ing strongly against engine (•Replace water temperature gauge monitor) •Replace thermostat (•Install radiator curtain) Engine does not start even when starting motor is turned •Lack of fuel •Air in fuel system •No fuel in fuel filter •Starting motor cranks engine too slowly •Starting motor does not turn •Defective valve clearance (defective compression) •Add fuel, see CHECK BEFORE STARTING (•Repair place where air is sucked in) •Fill filter with fuel.

See EVERY 500 HOURS SERVICE. •See ELECTRICAL SYSTEM •See ELECTRICAL SYSTEM (•Adjust valve clearance) Fuel stops from time to time •Clogged Fuel tank cap •(Clean or replace fuel tank cap)