Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE PROCEDURE MAINTENANCE 6. Direct dry compressed air (less than 0.69MPa (7kgf/cm 2 , 99.4PSI)) to the outer element (4) from inside along its folds, then direct it from outside along its folds and again from inside. 7. Remove one seal from the element whenever the element has been cleaned. 8. Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner ele- ment at the same time. 9. Replace both inner and outer elements when the monitor (1) flashed soon after installing the cleaned outer element even though it has not been cleaned 6 times. 10. Check that there is no play in the inner element.

If any play is found, push it in properly. 11. Remove the cloth or tape cover installed in Step 3. 12. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. NOTICE When cleaning the element, do not hit or beat it against any- thing. Do not use an element whose folds or gasket or seal are damaged. 13. When replacing the element, push the indicator button at the bottom of the air cleaner to reset it. 4-22