MAINTENANCE PROCEDURE MAINTENANCE CLEAN LINE FILTER, REMOVE DIRT 4 If there is any abnormality in the pump or other hydraulic equipment, remove the dirt from inside the line filter as follows. Before removing the line filter, release the pressure inside the hydraulic circuit. For details, see "METHOD FOR RELEASING INTERNAL PRESSURE IN HYDRAULIC CIRCUIT (4-40)". 1. Remove 4 bolts (1), then remove flange (2). 2. After removing 4 bolts (3), temporarily screw 2 of them into cover (4). 3. Remove cover (4) and wash filter (5). When washing the fil- ter, remove plug (6) and clean out all the dirt stuck to the side face of the case. 4. After washing filter (5), install it again.
When installing the fil- ter, cover, and flange again, replace backup ring (7) and O- rings (8), (9), and (10) with new parts. After assembling the filter again, bleed the air. For details, see "BLEEDING AIR FROM HYDRAULIC SYSTEM (4-37)". 4-34