MAINTENANCE MAINTENANCE PROCEDURE CLEAN ENGINE BREATHER 4 q The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature to go down before cleaning the engine breather. q When using compressed air, there is a hazard that dirt may be blown up and cause serious injury. Always use safety glasses, dust mask, or other protective equipment. 1. Wipe away dust around the breather. 2. Remove breather (1). 3. Rinse the whole breather in diesel oil or flushing oil. Dry with compressed air, then install it. 4. Replace O-ring with new one. Coat a new O-ring with engine oil, set it, then install breather (1).
CLEAN, CHECK TURBOCHARGER 4 Contact your Komatsu distributor for cleaning and inspection. CHECK ALTERNATOR, STARTING MOTOR 4 The brushes may be worn, or the bearing may have run out of grease, so contact your Komatsu distributor for inspection or repair. When the engine is frequently started, ask for inspection every 1000 hours or every 6 months, whichever comes sooner. CHECK ENGINE VALVE CLEARANCE, ADJUST 4 As special tool is required for removing and adjusting the parts, you shall request Komatsu distributor for service. CHECK INJECTOR 4 Check the color of the exhaust gas visually. If there is any abnormality in the exhaust gas color, contact your Komatsu distributor for inspection.
For details, see "TROUBLES AND ACTIONS (3-139)" "Exhaust color is black". 4-71 WARNING