DETAILED CONTROLS AND GAUGES OPERATION Horn Switch When the switch (8) at the tip of the right work equipment control lever is pressed, the horn will sound. Room Lamp Switch NOTICE It is possible to turn on the room lamp even when the starting switch is at the OFF position, so be careful not to forget to turn it off. This switch (9) is used to light up the room lamp. (a) ON position: Lights up (b) OFF position: Goes out It will also light up even when the engine is not running. Pump Drive Emergency Switch NOTICE The emergency pump driving switch is provided to make it possible to carry out work for a short time when there is a failure in pump control system.
It is necessary to repair the abnormal location as soon as possible. This switch (10) is used to make it possible to carry out operations temporarily if any abnormality should occur in the pump control system (when the display shows E02). (a) When abnormal : Move switch up (b) When normal : Move switch down If the display shows E02, move the switch up to make it possible to carry out work. 3-30