ford — Krystal Enterprises Bus Owners Manual

Air Operated - Single Plug Door 4-Way Valve Entry Door Ajar Switch Closing Cushioning Valve Closing Speed Valve Opening Speed Valve Opening Cushioning Valve Secondary Entry Door Switch - used on air operated door systems, located on passenger door post CAUTION! Never attempt adjustment of the Boomerang Arm, call KRYSTAL SERVICE Single Plug Door System (door shown partially open) Air Door Speed Adjustment Procedure 1. Remove the air motor cover located in the stepwell. 2. Using the photo on this page, identify the speed control valves. Using a 3/8” wrench, loosen the locknuts on both valves. 3.

Operate the door and adjust both valves until the opening and closing speeds are equal and acceptable. Then tighten both locknuts. 4. Using a fl at blade screwdriver, adjust the opening and closing cushioning valves on the air motor, then replace cover. Krystal Enterprises 46 RETURN TO MENU