Ricon Rear Door Wheelchair Lift Lift Motor Assy ATTENTION! When the green light is lit, the lift needs service Basic User Instructions Passenger Loading and Unloading Do not exceed the 800 pound load capacity of the lift. Prior to lift operation, the lift should be inspected for proper function. If any problems exist , DO NOT USE LIFT. Contact Ricon Corp. at 1-818-322-2884 for repair. Passengers loading from the ground level, should back onto the platform. All passengers loading onto the platform, should be positioned centrally on the platform, facing outward from the vehicle, with the wheelchair locks locked, and restraint belt fastened. Electric wheelchairs should be turned off.
UNFOLD The UNFOLD function deploys the lift from the upright position, with the platform extended fl at at fl oor level, with the roll stop vertical. FOLD The FOLD function raises the lift from the horizontal fl oor level position, bringing the platform back to a full upright position DOWN The DOWN function lowers the platform to the ground level, and ex- tends the roll stop to a fl at position, for wheelchair egress. UP The UP function raises the roll stop to full vertical position, before raising the platform from ground level to the fl oor level position for unloading. C A U T I O N ! Never raise or lower lift if roll stop is malfunctioning C A U T I O N !
YOU MUST READ AND UNDERSTAND THE MANUFACTURERS OPERATORS MANUAL BEFORE EVER OPERATING THIS LIFT C C Back-up Pump Lift Control YO Release Valve Pump Handle (not shown) Krystal Enterprises 54 RETURN TO MENU