Braun Under Vehicle Wheelchair Lift Lift Cl d Lift Closed Lift Extended Lift Lowered Lift Raised f f f Emergency Back-Up Operation In the event of an electrical system failure, the UVL system provides for full manual operation. Locate the manual release cable, manual down valve, and the hand pump on the power pack. To move platform from STOW , pull the manual release cable. Twist the “T” handle to lock in the released position. The plat- form can now be pulled outward. To raise the platform , make sure the manual down valve is turned fully clock- wise. Pump the hand pump handle until you reach the desired platform height.
To lower the platform , turn the manual down valve SLOWLY counter-clockwise to lower the platform. To lower the front barrier , remove the release pin at the barrier actuator end. Lift will not continue operating unless release pin is re-inserted fully. To move platform to STOW po- sition , fi rst be sure the platform is at STOW height. Pull and lock the manual release cable. Push the platform inward to re-engage release cable mechanism. Note: Refer to Service Manual for Maintenance, Adjustment, and Trouble Shooting Procedures Krystal Enterprises RETURN TO MENU 57