3-2 GENERAL ALTERNATOR NOTE 1. Cold cranking ampere : It means that terminal voltage is maintained 7.2V or more at a certain temperature and battery current is supplied for 30 seconds. 2. Reserve capacity : It represents the time can be supplied 25A from battery with minimum termi- nal voltage maintained 10.5V at 26.7°C. Item Specification Type Battery voltage sensing type Rated output 13.5V 90A RPM 1,000 ~ 18,000rpm Regulator adjusting voltage 14.4 0.3V/20°C Temperature compensation -10 3mV/°C Voltage regulator type Electro-magnetic, Built-in type