3-7 IGNITION SYSTEM SPARK PLUG ANALYSIS L4GC300A SPARK PLUG TEST After connecting the spark plug to the high tension cable, con- nect the outer terminal(main body) to the ground and crank the engine. Because the discharging clearance is narrow in the air, only slight spark will arise. But if the spark plug is normal, spark arises at emission clearance (between terminals), and if the spark plug is defective, spark does not arise because insula- tion is damaged.
Ignition coil Spark plug ECU Ignition switch Insulation damaged Insulation damaged Insulation damaged L4GC306A State Contact point is black Contact point is white Description •Density of the fuel mixture is thick •Lack of air intake • Density of the fuel mixture is thin •Ignition timing is fast •Spark plug is tight •Lack of torque