CHARGING SYSTEM 3-23 RECTIFIER 1. (+) rectifier When inspecting continuity between (+) rectifier and stator coil lead connecting terminal using an ohmmeter, there must have only one direction continuity. If there is both direction continuity, replace the rectifier assembly owing to short cir- cuit of diode. L4GC335A 2. (-) rectifier When inspecting continuity between (-) rectifier and stator coil lead connecting terminal using an ohmmeter, there must have only one direction continuity. If there is both direction continuity, replace the rectifier assembly owing to short cir- cuit of diode.
L4GC336A BRUSH REPLACEMEMENT If the brush is worn out to the limit, replace the brush as the following order. Wear limit L4GC337A INSTALLATION Installation is the reverse order of disassembly. Take care of the following items. 1. Before installing the rotor to the bracket, insert the wire into the small bore of rear bracket and fix the brush. 2. After installing the rotor, remove the wire. L4GC338A