PCV VALVE 4-17 SERVIE PROCEDURE REMOVAL 1. After disconnecting the vacuum hose(A), remove the PCV valve(B). A B L4GC264A INSTALLATION Install the PCV valve and connect the vacuum hose. INSPECTION B A 1. Remove the PCV valve. 2. Check the plunger for movement by inserting a thin stick (A) toward the valve (B) nut. 3. If the plunger is not moved, it means that PCV valve is clogging, so, clean or replace PCV valve. L4GC265A TROUBLESHOOTING 1. Disconnect the vacuum hose from the PCV valve. Discon- nect the PCV valve from the locker cover and reconnect the vacuum hose. 2. With the engine at idle, Check the intake manifold for vacuum when clogging the opened end of PCV valve.
NOTE The plunger in PCV valve will move back and forth. 3. If vacuum is not detected, clean or replace PCV valve and vacuum hose. L4GC266A Tightening torque 0.8 ~ 1.2kgf·m