John Deere 450H, 550H, 650H — Operating Fuel-Fired Coolant Heater—If Equipped

Operation—Operating The Machine 3. When the weekday has been adjusted, pressing (A) causes the display to stop flashing and the weekday to be stored. CED,OUO1032,1406 -19-03SEP02-2/9 Heating Without Programming (Time OFF) T121396B —UN—11MAY99 1. Switch On Heating: Briefly press (C). 2. Display window (F) will display (H) and heating time (G). The default heating time is set to 120 minutes. It can be changed permanently or temporarily. 1. Temporarily Setting New Heating Time: Briefly press (C). T121393 —UN—11MAY99 2. To decrease heating time (one minute increments), press (D). 3. To increase heating time (120 minutes maximum), press (E). 1. Switch Off Heating: Briefly press (C). 2.

The status display (H) disappears. Automatic after-run for cool-down purposes will begin. A—Time B—Program C—Heating On D—Backwards E—Forwards F—Display Window G—Heating Time Display H—Heat Status Display Continued on next page CED,OUO1032,1406 -19-03SEP02-3/9 2-2-11 070813 PN=49