Operation—Operating The Machine Using Booster Batteries—12 Volt System T6508AE1 —UN—24OCT91 T6713AI1 —UN—24OCT91 Single Battery Application Two Battery Application A—Machine Battery(s) B—Booster Battery(s) Before boost starting, machine must be properly shut down and secured to prevent unexpected machine movement when engine starts. 2. Connect one end of the negative cable to the negative terminal of the booster batteries. Then connect other end of the negative cable to the machine frame as far away from the machine batteries as possible. CAUTION: An explosive gas is produced while batteries are in use or being charged. Keep flames or sparks away from the battery area.
Make sure the batteries are charged in a well ventilated area. 3. Start engine. 4. Immediately after starting engine, disconnect end of the negative cable from the machine frame and disconnect the other end of the negative cable from the negative terminal of the booster batteries. Always remove grounded battery clamp first and replace it last. IMPORTANT: The machine electrical system is a 12-volt negative ground. Use only 12-volt booster batteries. 5. Disconnect positive cable from booster batteries and machine batteries. 1. Connect one end of the positive cable to the positive terminal of the machine batteries and the other end to the positive terminal of the booster batteries.
TX,25,BD2079 -19-14JAN08-1/1 Engine Warm-Up 2. Operate machine at less-than-normal loads and speeds until engine is at normal operating temperature. 1. After engine starts, run at 1/2 speed for 2 minutes. Do not run at fast or slow idle. 02T,25,M24 -19-03AUG92-1/1 2-2-17 070813 PN=55