OPERATION Operation Handling hydraulic quick coupler (option) Handling hydraulic quick coupler (option) 0. Before operating the machine, check that the attachment is correctly connected. If it is not correctly installed, the attachment may fall off and cause serious injury. Check that the quick coupler attachment switch is at the CONNECT position. Check that the coupler plunger is completely inserted into the attachment. REMOVING THE ATTACHMENT 0. 1. Tilt the attachment. 2. Keep the control lever at the TILT position, pull lock (A) of the quick coupler attachment switch in the direction of the arrow (c), and push in to RELEASE position (a) to release the connection.
NOTICE The alarm buzzer is sounding while the quick coupler attach- ment switch is at RELEASE position. 3. Check that the lock pins have been removed. The lock pin indicators may not be visible. 9JA04832A 4. Lower the attachment completely to the ground and set it in a stable position. WA250PZ-5 – VEAM945101 3-81 WARNING