Operation OPERATION Handling hydraulic quick coupler (option) 9. Check that the coupler plunger is completely inserted by the lock pin indicators on left and right.. Indicator Indicator G025022 Removal and installation of the attachment 0. The hydraulic system is always under internal pressure. When replacing and installing the coupling, release the pressure inside the circuit. If the circuit is still under the pressure, high-pressure oil will spurt out and lead to serious injury. 1. Lower the work equipment to the ground, stop the engine, then operate the extra control lever fully 4 or 5 times. This will release the pressure inside the hose. 2.
Raise sleeve (2) of coupling (1), insert coupling (3), then return sleeve (2) to its original position to complete the con- nection. 3. Pull the hose to confirm that it is connected securely. Precautions for use 0. Check that the lock pin has been inserted securely, then operate the lift arm and bucket control levers. Precautions when removing the attachment 0. Before removing the attachment, disconnect the hydraulic coupling. 3-84 WA250PZ-5 – VEAM945101 WARNING