. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE 4 - 27 3. Open dr ain valve (3) under the r adiator, drain plug (4) at the side fac e of the engine, and drai n plug (5) under the vib ration damper, and drain the coolant. 4. After dra ining the coolant, close d rain valve (3) and drain plugs (4) and ( 5), and fill with city water . 5. When th e radiator is full, start the engine, and run it at lo w idle. Keep th e engine running at low idle for 10 minutes un than 90°C (194°F). til the water te mperature reaches more 6. Stop the engine, open drain valve (3) and drain plug (4) a nd (5), and drai n the water. After drainin g the water, close them . 7.
After dra ining the water, clean the cooling system with cleaning agent. For the cleaning method, see the instructions for the cleaning 8. agent. After the cleaning, open drain valve (3) and drain plug (4) and 9. (5), and Close dr drain all of the water. ain valve (3) and drain p lug (4) and (5). 10. Replace the corrosion resistor, th en set valve (1) to the OPEN position to open it. placing corrosion r For re CORRO SION RESISTOR CART 11. Add coo water fill Decide t he proportions of antifree ze and water according to the 12. table for To remo the mixing rate of water ve the air contained in t and antifreeze.
he coolant, run the engine at low idle for 5 minutes, then run f or another 5 minutes a t high ) idle. (W hen doing this, leave the coolant filler cap OFF. 13. Stop the engine. About 3 minute s later, supply the cool ant up to the co olant filler, then close ra diator cap. 14. Drain th e coolant from inside of s ubtank (6), flush the ins ide of the subt ank, then fill with the co d LOW marks. olant to a point between the FULL an