. MAINTENANCE SERVICE PROCEDURE EVERY 4000 HOURS SERVICE CHECK VIBRATION DAMPER CHECK INJECTOR See Section "B REGULATION AREA (PAGE 4-21)". REPLACE INJECTOR ASSEMBLY See Section "A REGULATION AREA (PAGE 4-21)". CHECKING FOR LOOSENESS OF HIGH-PRESSURE CLAMP, HARDENING OF RUBBER 4 - 76 Maintenance f or every 50, 100, 250, 500, 100 0 and 2000 hours service should be c arried out at the same tim CHECK WATER PUMP Check f or play in the pulley, leakage of grease or water, or clogging of the drain hole. If any proble m is found, contact your Komatsu distributor for disassembly and repair or replacement.
CHECK AIR COMPRESSOR Ask you r Komatsu distributor to carry out this CHECK FAN PULLEY AND TENSION PU Check f or play of the pulley and leakage of grea se. If any problem is found, please contact your K omatsu distributor. There is the po ssibility of drop in the level of the damper fluid and runout of the concav e surface. So, please contact your Komatsu distributor to inspect or replace. See Section " See Section " Check v isually and touch with your fingers to check that there are no loose bolts or hardenin g of rubber part s at clamps (1) to ( 15). If there is any looseness or hardened rubber, contact your Komat su distribu tor for replacement.
NOTICE The f uel spray p revention cap and fuel spray preven tion cover are protective parts to prevent fi re if leaking fuel should spra y on high-temperatur e parts of the engine. d fuel spray prevention cover are installed correctly. Always c heck th at the fuel spray prevention cap an d fuel spray prevention cover are installed