. ATTACHMENTS, OPTIONS HANDLING AUTO-GREASING SYSTEM and greasing plan for the NOTICE sorrounding area dirty. 6 - 33 SETTING GREASIN The set time and gre machine, so set the fo llowing items to carry out suitab le centralized greasing. Greasing interval ( Hr): Greasing interval for automa Greasing time (min ): Length of time pump is operat ed for each greasing operation Greasing frequenc No. of times for op erating pump before the 1600 cc grease cartridge becomes empty The settings when shi pping from the factory are as fol Greasing interval: 3 h Greasing time:
15 min Greasing frequency li The grease level alar m is set to sound after 300 hours on the hourmeter (whe n normal Be c areful since the life o f grease cartridge will be shortened if the greasing interva l becomes shorter . Also, if the gr easing interval becomes shorter, the am ount of grease dripping from the ti p of the working machine i ncreases. I t may m ake th e machine and Setting greasing time i n cold areas In c old temperatures, the viscosity of the grease incre ases and the resistance inside th e pipin g becomes greater, so i t is necessary to e xtend the length of the greasing operations in orde r to ensure that the greasing is carried out properly.
If the machin e is used in ambient temperatu res below -20°C (- 4° F), set the greasing time t o 20 minutes (code No. 7). In additi on, use lithium-based grease No . 0. For details of setting t he time, see "METHOD OF SET When changing the se t value, please contact your Ko