Komatsu — METHOD OF OPERATING AUTO-GREASING SYSTEM

. ATTACHMENTS, OPTIONS HANDLING AUTO-GREASING SYSTEM GREASING WARNING 6 - 36 Air b leeding of pump i nvolves danger becau se of high pressure. Ask your Komatsu distribut or for air bleedin NOTICE Afte r greasin g, be sur e to r eset the count of the controller. ( See "TROUBLESHOOTING (PAG use the procedures , taking care not to let air or dust get in to the grease. S upply grease w hile the ambien t temperature is above -10° C (14 °F) 1. Prepare 18-k ower plate pump against the g reasing surface, then in sert the pump and set speci al cover (1) to th e pail. Then, op erate the handle of the p ump and confirm that clean grease come s ou t of the ho se end. 2.

Remov e the ca p of t he grease filler of the pump a nd screw in t he hose fitting, t hen operate th e pum 3. When g reas e is supplied for the fir st time, there is u sually so me air under the follower plate (2). If grease is supplie d to t he u pper limit, however, the air is bled through the sm all hole on the s ide of the tank. When supplying grease next tim e an d there after, st op supplying i t when it reac hes the bottom of this air bleed hole. 4. After su pplying grease, remove the hose fitting an d fit t he cap to the grease filler of the grease p ump w ithout fail. Keep th e pump and pail in a clean