. OPERATION OPERATION OPERATION OPERATION 6. When the engine starts, release the key in starting switch (2). The key will automatically return to the ON position. 3 - 109 3. Chec engine pre-heating pilo panel lights If the engine pre-heating p ilot lamp does not lig ht, go t o ste p 5. 4. Keep in this condition until engine pre-heating pilot lamp (3) is completed after approx. 12 seconds, and the ut.) amp (3) goes out. (Pre-heating lamp goes o engine pre-heatin 5. When engin e pre-heating pilot l am p (3) goes o ff, turn the key of starting s witch (2) to the START p osition to cr ank the engine.
The t ime t hat engine p re-heating pilo t lam p (3) s tays on changes ac cording to t he ambient te mperature as shown in the table below. Ambient temperature Pre-heat time 0°C to -10°C (32°F to 14°F) 0 to 15 seconds -10°C to -20°C (14°F to -4°F) 15 to 30 seconds -20°C to -30°C (-4°F to -22°F) 30 to 45 seconds -30°C to (-22°F to) 45 seconds