. MAINTENANCE SERVICE PROCEDURE CLEANING OR REPLACING OUTER ELEMENT 4 - 20 1. R emove wing nut (1 ), then remove outer el 2. C lean the inside of t 3. D irect dry compres sed air (Max. 0.69 MP a (7 kg/cm 2, 99.4 P di a SI)) from the inside of the outer element al ong its folds . Then rect the compress ed air from the outside a long the fol ds, and gain from the insid e. 1) Remove one se al from the element whe never the e lement has been cleane d. er element if it has been cleaned 6 times 2) Replace the out repeatedly or us element at the s ed throughout a year. Replace the inner ame time.
ner clogging warning display is given er the outer element has been cleaned, s not been cleaned 6 times, replace the nd outer elements. ment mounting nuts for looseness and, if hten. ner parts are found on the element when 3) If the air clea immediately aft even when it ha both the inner a 4) Check inner ele necessary, retig 4. If small holes or thin ner parts are found on the elemen t when it i th s checked by shin ing a light through it afte r cleaning, r eplace e element. 5. If seal washer (4) is damaged or the thread of nut (3) is broken, re place with new pa rts. NOTIC E When cleaning the element , do not hit or beat it agai nst anything.
Do not use an element who se folds, gasket or seal ar e damaged. 6. S et the cleaned ele