Komatsu — ELECTRIC HEATER

. ATTACHMENTS, OPTIONS STARTING IN COLD AREAS MANUFACTURING EXTERNAL POWER SOURCE INPUT CABLE The external power source input cable must be made locally to match the local conditions, but this does not mean that any type of cable can be used. The following explains the procedure for making the cable and precautions to be followed when making it, so follow this procedure when making the cable. Cable specifications and installing procedure 1. Purchase locally a 3-core Type 2 EP rubber insulated heavy-duty chloroprene sheath cable, using the specifications in the diagram on the right for reference. The nominal cross-sectional area of one core should be 14 mm 2 .

Use a cable with a voltage resistance capacity of 3000 V for 1 minute. To prevent any drop in the voltage, keep the length within 30 m (98 ft). 2. Connect the machine input connector (sent as an individual part) 426-06-11630 (Connector) to the end of the cable. The connector has 3 contacts and each is provided with a code, so connect the cable core wires as shown in the chart below. CAUTION 3. Modify the other end of the cable so that it can be connected to the power supply facility shown in Diagram 1. When the connection modification is finished, the external power source input cable is completed.

6 - 5 Always weld the connections between the connector and the core w Fit the welding parts with a rubber tube or wrap with insulating tape caused by contact between semiconductors. Always use 426-06-11630 for the connector. If any other connector power source input receptacle.