CLAAS ACADEMY LEXION II General hydraulics Contents 1.1 Oil tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Oil specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Oil change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Oil filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Oil pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 General hydraulic problems . . . . . . . . . . . . . . . . . 1-3 General hydraulics 1.2 Hydraulic pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 1-4 Working hydraulics . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Steering hydraulics . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Uni-spreader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Chaff spreader . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Straw spreader . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Side knife for rape . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Sauer hydrostatic drive . . . . . . . . . . . . . . . . . . . . . 1-6 Sauer charge pump . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Linde hydrostatic drive . . . . . . . . . . . . . . . . . . . . . . 1-7 Linde charge pump . . . . .
. . . . . . . . . . . . . . . . . . . . 1-7 11/2001 1-1
General hydraulics LEXION II CLAAS ACADEMY 1.1 Oil tank for the complete hydraulic system 1-2 11/2001
CLAAS ACADEMY LEXION II General hydraulics Key to diagram 112 - Return flow filter 729 - Pressure relief valve for low pressure (starting in 2002) . . . . . . . . . . . . . . . . . . . . . . . . . 19 +4 bar 731 - One-way valve Z19 - Hydraulic oil level switch (min.) Z20 - Hydraulic oil temperature . . . . . . . . . . . . . . . . . . .
103°C A - Suction connection – working hydraulics pump B - Suction connection – Uni-spreader or chaff spreader C - Suction connection – Steering hydraulics D - Return feed from hydrostatic drive and steering hydraulics E - Return feed for working hydraulics, Uni-spreader or chaff spreader F - Return flow filter K - Oil level dipstick with breather L - Oil drain pipe Oil specification General hydraulic oil conforming to (ISO VG 46), DIN 51524 part 3 Quantity Total hydraulic system = 40 - 60 litre, depending on specification Hydraulic tank = approx. 10 litre Oil change First change after the first 100 operating hours, then either yearly or every 500 hours whichever is sooner.
Check the oil level with the cutterbar rams retracted. Oil filter Working hydraulics = sieve filter in the tank (60 µm) Steering hydraulics = sieve filter in the tank (60 µm) Hydrostatic drive = filter cartridge (10 µm) Change filter yearly or every 500 operating hours whichever is sooner. Oil pressure Working hydraulics = 175 +15 bar, back pressure 3 +6 bar Steering = 160 +15 bar, back pressure 10 +7 bar Low pressure hydraulics = 19 +4 bar High pressure ground drive = 420 +30 bar Charge pressure ground drive = 30 ± 2.5 bar Chaff spreader / straw spreader = 175 +15 bar Uni-spreader = 55 +15 bar Note:
These figures are to be measured, when the hydraulic oil is at a working temperature of approx. 60°C General hydraulic problems Hydraulic tank overheating Excessively high back pressure in the system (p max back pressure - Check the spool operation in the returns valve - Check the hydraulic pipes for kinks - Check the return filter for cleanliness Note: If the machine is equipped with Autopilot, then also look in the chapter on steering hydraulics. 11/2001 1-3