19-136 19-136 Electrical System Troubleshooting Error codes H1-1, H1-2, H1-3, H1-4 Disconnect the battery negative terminal, after inspecting and correcting disconnection and water entry of A21, A23, AO3, XO3, YX1 and Y6, reconnect all connectors and the battery negative terminal, turn the ignition key switch ON, and check whether or not there is an error. No error Connector contact defect Error Turn the ignition key switch OFF, disconnect the battery negative terminal, replace the lift lever potentiometer with the tilt lever potentiometer, and check if there is any change in the error. H2-4 OK Inspection 1:
Lift lever potentiometer inspection Installation defect NG H1-* Lift lever potentiometer abnormality H2-1·H2-2·H2-3 Inspection 2: Harness continuity and short circuit inspection NG Harness defect OK Replace fuse NG Fuse inspection OK SAS/OPS/mini lever controller defect Note: If the lever has been removed, be sure to perform matching after the lever is reinstalled. Inspection 1: Carry out lift lever potentiometer inspection. Ignition key switch OFF, return the lift lever potentiometer and tilt lever potentiometer to their original positions, check lift lever potentiometer installation (refer to section 18), ignition key switch ON, match lift lever potentiometer Section 19