19-155 Electrical System Troubleshooting z Error code HA-1 (3/4-way change relay abnormality) Related portion IG Probable cause c Connector contact defect d 3/4-way change relay 1 harness defect e 3/4-way change relay 1 defect f 3/4-way change relay 2 harness defect g 3/4-way change relay 2 defect h SAS/OPS controller defect Error code HA-1 3/4-way change relay defect Harness defect SAS/OPS/mini lever controller defect Inspection 1: Inspect for continuity and short circuiting of the harness. Ignition key switch OFF, disconnect A21 and each relay Standard:
Section 19 A21 1 3/4-way change 12 (ATSO) 2 relay 1 SAS/OPS/ Mini lever controller 3 3/4-way change 4 relay 2 SAS/OPS/ Mini lever controller 3/4-way change relay 2 Disconnect the battery negative terminal, after inspecting and correcting disconnect and water entry of A21, reconnect A21 and the battery negative terminal (leave relay disconnected), turn the changeover switch to the 3-way side, turn the ignition key switch ON, and check whether or not there is an error. No error Error Inspection 1: Harness continuity and short circuit inspection OK A21-12 ~ Relay terminal 2 Continuity A21-12 ~ Relay terminal 4 Continuity A21-12 ~ Frame No continuity