19-175 Electrical System Troubleshooting Section 19 Corrective action If there is no change, perform an installation check or replace the sensor. Follow matching procedure to rematch. If there is no change, perform an installation check or replace the sensor. Follow matching procedure to rematch. Harness check or replace switch Replace Checking method Load sensor voltage check: Check that the voltage rises on lift relief. – Tilt angle sensor voltage check: Tilt to forward and backward tilt positions and check the voltage change. – ON/OFF check with analyzer. – Malfunction area · mode Load sensor unit: Sensor defect Load sensor line (Power supply, signal, ground):
Disconnection fault (Harness, connector) Short or leak fault (Harness, connector) Load sensor no-load matching value: Does not match actual status (rematch) Tilt angle sensor unit: Sensor defect Tilt angle sensor installation: Link, installation part destroyed, damaged Horizontal matching value for tilt angle sensor: Does not match actual status (rematch) Lifting height switch unit (2200H): Disconnection fault (internal damage, stuck) SAS/OPS controller: Controller defect Phenomenon on vehicle Forward tilt automatic fork leveling does not stop. (Stops at the position where the automatic fork leveling switch is pressed) Control type Tilt control