Maintenance - Section 4 OM4035.2 02/03 Page 4- 28 Automatic Lube System POSSIBLE CAUSES SUGGESTED CORRECTIVE ACTION TROUBLE: Timer Turns On At Intervals Two (2) To Ten (10) Times More Often Than Set Time Interval Electrical noise is being introduced into the power sup- ply to the timer overcoming suppressor capacitor causing uncontrolled turn-on of its output relay. IMPORTANT: In some instances, electrical noise may be generated into vehicle electrical system which may cause timer to turn on at random inter- vals, independent of timer setting.
If this occurs, a 250 to 1,000 MFD capacitor rated 150 to 350 VDC should be added across BAT (+) and BAT (-) terminals to suppress this noise and im- prove timer performance. TROUBLE: Timer Turns On At Intervals Faster Than Allowable Tolerances Of Settings Timer out of adjustment or damaged component. Refer to “Timer Adjustment and re-adjust timer or replace timer.