Komatsu — 10 HOUR (SHIFT) LUBRICATION AND MAINTENANCE CHECKS

Maintenance - Section 4 OM4035.1 01/04 Page 4-4 Lubrication and Service 10 HOUR (DAILY) INSPECTION Prior to each operating shift, a “walk around” inspection should be performed. Check the truck for general con- dition. Look for evidence of hydraulic leaks; check all lights and mirrors for clean and unbroken lenses; check operator's cab for clean and unbroken glass; check frame, sheet metal and body for cracks. Notify the proper maintenance authority if any discrepancies are found. Give particular attention to the following: Truck Serial Number __________________________ Site Unit Number _____________________________ Date:

__________ Hour Meter __________________ Name of Service Person _______________________ NOTE:“Lube Key” references are to the Lubrication Specification Chart. 1. FAN DRIVE AND TURBOCHARGERS - Check for leaks, vibration or unusual noise. Check alternator and fan belts for proper tension, condition and for align- ment. 2. RADIATOR - Check coolant level and fill with proper mixture as shown in Cooling System Recommendation Chart. Refer to Engine Manual for proper DCA levels. 3. ENGINE - Check oil level. Refer to engine manufac- turer's manuals for oil recommendations. Lube Key "A". 4. FUEL FILTER - Drain water from bottom of filter housing. 5.

FUEL STRAINER - Drain water and sediment at drain cock. 6. MOTORIZED WHEELS - Refer to G.E. Motorized Wheel Service & Maintenance Manual for lubrication specifications and service intervals. 7. HYDRAULIC TANK - Check oil level in tank, add if necessary. Refer to "Hydraulic Tank Service". Oil should be visible in sight glass. - DO NOT OVERFILL. Lube Key "B". 8. AIR CLEANERS (NOT SHOWN) - Check air cleaner vacuum gauges in operator cab. The air cleaner(s) should be serviced, if the gauge(s) shows the following maximum restriction: Komatsu Engine: 25 in. of H2O vacuum*. NOTE: After service, push the reset button on face of gauge to allow the gauge to return to zero. COMMENTS CHECKED INITIALS