. OPERATION TROUBLES AND ACTIONS Machine Monitoring System (*): For details of handling the emergency pump drive switch, see "Emergency Pump Drive Switch (PAGE 3-39)". 3 - 158 Electronic Control System When the user code is shown on the display portion o f the machine monitor, take the respective measures shown in the self-diagnosis chart below. Monitor display Failure mode Action E02 Pump control system error When emergency pump drive switch is at the up (emergency) position, normal operations become possible, but have inspection carried out immediately. (*) E03 Swing brake system error Have inspection carried out immediately.
E06 Electrical system error If the emergency work equipment actuation switch is turned ON, the work equipment (boom) can be raised, but have the machine inspected immediately. E10 Engine controller power source error Engine controller drive system circuit error (engine stooped) Have inspection carried out immediately. E11 Engine controller system error (output reduced to protect engine) Operata machine to a safe posture and have inspection carried out immediately. E14 AbnomalIty in throttle system Operata machine to a safe posture and have inspection carried out immediately.
E15 Engine sensor (coolant temparature, fule pressure, oil pressure) system error Operations are possible, but have inspection carried out immediately. E0E Network error Operata machine to a safe posture and have inspection carried out immediately. In the case where the monitor will not display error codes and work equipment operation and swing operation cannot be carried out. Have inspection carried out immediately.