Komatsu — EVERY 4000 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE CHECK FOR MISSING FUEL SPRAY PREVENTION CAP, HARDENING OF RUBBER 4 - 79 The f uel spr ay prevention caps (14 places) on the fuel i njection piping and both ends o f the high-pressure piping act to prevent th e fue l from coming into contact with high-temperature parts of the engin e and causing a fire if the fuel shou ld leak or spray out. Check vis ually and touch by hand to check that there are no missing caps, loose bolts or hardening o f the rubber. If there a re any problems, the parts must be replaced. In this case, please ask your lacement. Komatsu dis tributor to carry out rep CHECK OPERATING CONDITION OF COMPRESSOR Check the following two items.

Chec k the fo llowing two items. 1. W hen th e air conditioner switch is turned ON-OFF, do the compressor and magn et clutch also turn ON-OFF? 2. I s any a bnormal noise generat ed by the clutch or c ompressor body? bled, repaired, or replaced. If any proble m is found, contact yo ur Komatsu distributor to have the parts disassem