Komatsu — SWITCHES

. OPERATION DETAILED CONTROLS AND GAUGES This switch (9) is used to make it possible to carry out operations temporarilyif any problem should occur in the pump control system (when the display shows "E02"). (a) EMERGENCY: When abnormal (move switch up) (b) NORMAL: When normal (move switch down) If the display shows "E02", move the switch up to make it possible to carry out work. This switch (10) is used to make it possible to carry out operations temporarily if any problem should occur in the swing parking brake system (when the upper structure does not swing but the display does not show "E03"). (a) FREE: When abnormal (move switch up) (b) NORMAL:

When normal (move switch down) If the display does not show "E03", move the switch up to FREE position (a) to make it possible to carry out work. When the switch is moved to FREE position (a), the swing lock monitor flashes. 3 - 39 Emergency Pump Drive Switch NOTICE This switch is provided to ena when emergency. Furthermore, remove the cause of the problem If this switch is depressed and moved to the EMERGENCY position by mistake, thereby e ngaging the mach ine in the work, condition, an "E02" mark is shown in th e display. work, check that the switch is in the NORMAL position.

Swing Parking Brake Release Switch NOTICE This switch makes it possible to p erform swing operations for a short eve n when there is a pr oblem i n the swin g parking brake electric system. DO NOT use this switch except in emergencies. Repair the problem as soon as possible.