Hitachi Construction Machinery — Control by Electric and Hydraulic Combined Circuit

SYSTEM / Control System Lift Arm Auto-leveler Downward Control (Op- tional)(ZW220) Purpose: Free locating of the lift arm between the ho- rizon and the lowest position Operation: 3. Pressure oil from the main pump flows into the rod end port of the lift cylinder through the lift arm spool of the control valve, and lowers the lift arm. 1. If the SET position of the lift arm auto-leveler downward set switch is selected after the lift arm is located within the allowable location of the lift arm auto-leveler (b’ in the illustration), signal from the lift arm angle sensor is memorized by the MC, and that is the lift arm auto-leveler downward lo- cation. 4.

When the lift arm angle sensor moves down to the lift arm auto-leveler downward locating position, earthing of #242 terminal of the MC is released, and the electromagnet on the lift arm downward end is unexcited for a while until it is excited again soon after. NOTE: When the lift arm is outside b’, even if the SET position of the lift arm auto-leveler downward set switch is selected, setting of the lift arm auto- leveler downward cannot be made. In case setting was thus unsuc- cessful, or setting in a different position is needed, make setting again with the above in mind. 5.

Thus the lift arm operation lever returns to the neutral position, and supply of pilot pressure from the pilot valve to the control valve is stopped. 6. As the lift arm spool of the control valve also re- turns to neutral, the lift arm stops at the lift arm auto-leveler downward stop position. Position of Lift Arm Tip Pin Position of Lift Arm Foot Pin NOTE: In case the lift arm angle sensor becomes out of order, the lift arm auto-leveler downward control is not made. IMPORTANT: In case either the lift arm angle sensor or the MC has been replaced, be sure to make learning control of the lift arm angle sensor.

(Refer to the OPERATIONAL PERFORMANCE TEST/Adjustment) b’ (Lift Arm Auto-leveler Downward Allowable Set- ting Range) b (Lift Arm Downward Work Range) 2. When the lift arm auto-leveler downward switch is turned ON, #242 terminal of the MC is earthed, and excites electromagnet on the lift arm down- ward end of the pilot valve. When the lift arm op- eration lever is moved to the lift arm downward detent position (position farther than the down- ward position), the lift arm operation lever is re- tained by the electromagnet on the lift arm downward end, and pressure oil is supplied to the control valve from the pilot valve. T2-1-70