Hitachi Construction Machinery — Pilot Circuit

SYSTEM/Hydraulic System Charging Block Circuit Charging block is installed for supplying pressure oil from the pilot pump preferentially to the service brake circuit, while distributing it to other pilot circuits as well. When the engine is started, oil is delivered from the pilot pump, and enters the charging block. At this time, when the amount of accumulated pressure of the service brake accumulators is low, the relief valve is closed. In this case, only pilot pressure is applied to Port B of the priority valve, but both the pilot pressure and the spring force are applied to Port A. So, the priority valve moves right, restricting pressure oil to flow further.

Pressure oil from the pilot pump flows toward the service brake circuit through the check valve, and accumulates the service brake accumulators. (to be continued to T2-3-20) NOTE: Spring of the priority valve is so adjusted that the valve is not completely closed. Even in the minimum opening condition, a certain amount of pressure oil is being supplied to the circuits downstream. T2-3-18