Hitachi Construction Machinery — Pilot Circuit

SYSTEM/Hydraulic System When the service accumulators are pressurized to a certain amount, the relief valve opens, and pressure is lost because Port A of the priority valve is connected to the hydraulic oil tank. Pressure at Port B of the priority valve causes larger force than the spring force, and moves the priority valve spool left. So, pressure oil from the pilot pump is all supplied to the priority valve and the circuits downstream. Pressure oil from the priority valve is supplied through each port to the respective pilot circuits.

When pressure in the pilot circuit rises higher than a certain amount, the pilot relief valve opens, and prevents components of the pilot circuit from being damaged. Pressure oil from Port PS1 passes the steering pilot valve to be supplied for actuation of the steering valve spool. (Refer to Steering Circuit.) Pressure oil from Port X changes its flow in response to the stroke of the pump torque control solenoid valve which is controlled by the signal from MC, and is used for controlling the main pump regulator. (Refer to Pump Control Circuit.) Pressure oil from Port BR3 is supplied for parking brake release pressure by operation of the parking brake solenoid valve.

(Refer to Parking Brake Circuit) Pressure oil from Port PS2 is supplied for controlling the servo piston of the main pump (Refer to Pump Control Circuit.) and the spool of the ride control valve (Refer to Ride Control Circuit.). Pressure oil from Port PP enters each pilot valve through the pilot shutoff valve, and is supplied to the control valve for actuation of the spool. (Refer to Front Attachment Operation Control Circuit.) T2-3-20