SYSTEM/Hydraulic System Front Attachment Operation Control Circuit (ZW220) Pressure oil from the pilot pump flows the charging block, and comes out of Port PP of the charging block to be supplied to each pilot valve through the pilot shutoff valve. Priority valve of the charging block supplies pressure oil preferentially to the service brake circuit when pressure in the service brake accumulators are lowered. (Refer to Charging Block Circuit.) Pilot shutoff valve is a manually operated type, and is installed for prevention of accidents due to mistaken operation by stopping suppy of pressure oil to the pilot valve when it is closed.
By controlling each pilot valve, pressure oil from the pilot pump shifts the control valve spools. At both ends of the spool for the lift arm cylinders of the control valve, slow-return valves are installed for moderating sudden movement of the spool. T2-3-22