Hitachi Construction Machinery — Serge Voltage Prevention Circuit

SYSTEM/Electric System SURGE VOLTAGE PREVENTION CIRCUIT When the engine is stopped (key switch: OFF), the electric current from Terminal M of the key switch is stopped, and the battery relay is turned OFF. Even if the key switch is turned off, the engine does not stop immediately keeping freewheeling, and the alternator continues generation of electricity. As the generated electric current does not flow to the battery, surge voltage (voltage rise) is generated, resulting in causes for failures of electronic equipment like the controller and other parts. For this reason, the surge voltage protection circuit is provided.

During charging, the electric generation current from Terminal L of the alternator enters #119 Terminal of the monitor unit. Monitor unit earths #33 Terminal to the ground. Electric current flows to the excitement circuit of the load dump relay, and the load dump relay works. Therefore, even if the key switch is turned OFF during rotation of the engine, the electric current from the battery keeps exciting the battery relay through the load dump relay. Also, the battery relay is turned OFF about ten seconds after the alternator stops generation of electricity. T2-4-16