SYSTEM/Electric System REVERSE LIGHT/BUZZER CIRCUIT When the key switch is turned ON, the electricity from the power source coming out of Terminal M excites the battery relay through #54 and #55 Terminals of Fuse Box A. Electricity from the battery power source enters #99 Terminal of Fuse Box A, and enters the reverse light relay through #108 Terminal. When the forward-reverse lever is turned to reverse, Terminal R is earthed, and the MC earths #109 Terminal because the electricity from the power source flows to the forward-reverse lever through #84 Terminal of the MC.
As a result, the reverse light relay is excited, and the electricity from the battery power source flows to the reverse light and the reverse buzzer. T2-4-28