COMPONENT OPERATION / Control Valve ZW250 Operation of Relief Valve 1. Pressure at port HP (in the main circuit) works on the pilot poppet through orifice A of the main poppet and orifice B of the seat. 2. When the pressure at port HP rises to the setting force of spring B, the pilot poppet opens, and pressure oil flows to port LP (in the hydraulic oil tank) passing through passage A and the periphery of the sleeve. 3. At this time, pressure difference arises between port HP and the spring chamber, caused by orifice A. 4. When this pressure difference reaches the value corresponding to the set force of spring A, the main poppet opens, and the pressure oil at port HP flows to port LP. 5.
As a result, pressure in the the main circuit lowers. 6. If the main circuit pressure lowers to the set pressure, the main poppet is closed by the force of spring A. T3-2-24