Hitachi Construction Machinery — Restriction Valve

COMPONENT OPERATION / Control Valve RESTRICTION VALVE Restriction valve is installed at the inlet part to the pilot circuit on the both ends of the spool for the lift arm. If the pilot valve is made at the neutral position during operation of the lift arm, the pilot pressure oil having been supplied to the spool for the lift arm is drained through the orifice of the check valve of the restriction valve, and pilot pressure gradually lowers. As a result, shock to the body occurring in operation of the front attachment can be reduced by gradually returning the lift arm spool to the neutral position. Check Valve Orifice Spool End Pilot Valve End T4GB-03-02-014 T3-2-31