COMPONENT OPERATION / Hydraulic Fan Motor FLOW CONTROL VALVE In case the cooling water and oil are below the set temperature, the flow control valve supplies necessary amount of the pressure oil from the fan pump, and returns redundant amount to the tank to make control for lowering the engine load and wind noise of the cooling fan. Operation 1. Pressure oil flowing from port P works on the A end as upstream pressure of flow control valve orifice (8), and on the B end as its downstream pressure, and the differential pressure works on flow control valve spring (12). 2.
When the pressure difference becomes larger than the set force, flow control valve spool (8) moves, and redundant flow flows to port T. T3-3-6