COMPONENT OPERATION/Pilot Valve During Metering or Pressure Decrease (Output Diagram: between C and D) 1. When the control lever is further tilted and pusher (2) is pushed down, hole part (7) of spool (6) reaches port P, and the prsessure oil from port P flows into the output port. 2. Pressure at the output port works on the bottom of spool (6), and tends to push up spool (6). 3. In case the force working on spool (6) is smaller than the spring force of balance spring (4), balance spring (5) is not compressed. Therefore, spool (6) is not pushed up, and the pressure at the output port keeps rising. 4.
When the pressure at the output port rises further, the force tending to push spool (6) up increases. If this force becomes larger than the force of the balance spring (4), spool (6) moves upwards, compressing the balance spring (4). 5. When spool (6) moves upward, hole part (7) closes, pressure oil stops flowing from Port P to the output port, and pressure increase at the output port is stopped. 6. In this way, the balance spring (4) is compressed by the amount spool (6) is pushed down, and the pressure at the output port is the balanced pressure working on the spring force and spool (6). F E D C B A Lever Stroke T523-02-05-001 Output Diagram T3-6-20 Pilo Pre t ssure