COMPONENT OPERATION / Ride Control Valve OPERATION 1. At neutral, port Pi and the ouput port are not connected, blocked by the spool. 2. When the signal from the MC (Main Controller) enters the solenoid, the solenoid is excited. 3. Solenoid pushes the spool with the force corresponding to the signal from the MC, so port Pi and the output port are connected, and pilot pressure oil pushes the main spool. 4. When the main spool is pushed toward spring 2, port A (on the bottom end of the lift arm cylinder) and the ride control accumulator are connected, and port B (on the rod end of the lift arm cylinder) and port T are connected. 5.
As a result, the pushing force of the lift arm cylinder is absorbed by the accumulator, and the load generated by the pushing up force is absorbed by sucking up the hydraulic oil from the tank port. Section A * To Ride Control Accumulator Port Pi Spool Pilot Pressure Port A Port B Spring 1 Output Port Spring 2 T4GB-03-08-006 Tank Port Main Spool *Refer to T3-8-1. T3-8-4