Hitachi Construction Machinery — Over Load Relief Valve

COMPONENT OPERATION / Ride Control Valve OVERLOAD RELIEF VALVE Overload relief valve is installed for preventing hoses and the ride control accumulator from being damaged in case the pressure in the bottom end circuit of the lift arm cylinder is suddenly raised by an external force or something during operation of the lift arm cylinder. Operation 1. Pressure at port HP (in the main circuit) works on the pilot poppet, passing orifice A of the main poppet and orifice B of the seat. 2. When the pressure at port HP rises to the setting force of spring B, the pilot poppet opens, and pressure oil flows to port LP, passing passage A and the periphery of the sleeve. 3.

At this moment, pressure difference arises between port HP and the spring chamber caused by orifice A. 4. When this pressure difference reaches the value corresponding to the set force of spring A, the main poppet opens, and the pressure oil at port HP flows to port LP. 5. As a result, the pressure in the actuator circuit lowers. 6. If the actuator circuit pressure lowers to the set pressure, the main poppet is closed by the force of spring A. IMPORTANT: Never disassemble or adjust the overload relief valve. Replace the whole assembly, when necessary. T3-8-8